Posted on

Download PDF by D A Conley; Jerald L Edson; C F Fineman; Idaho National: Aging study of boiling water reactor high pressure injection

By D A Conley; Jerald L Edson; C F Fineman; Idaho National Engineering Laboratory.; U.S. Nuclear Regulatory Commission. Office of Nuclear Regulatory Research. Division of Engineering

Show description

Read or Download Aging study of boiling water reactor high pressure injection systems PDF

Best nonfiction_7 books

Download e-book for kindle: Evolutionary Computation in Dynamic and Uncertain by Dr. Shengxiang Yang (auth.), Dr. Shengxiang Yang, Dr.

This e-book presents a compilation at the cutting-edge and up to date advances of evolutionary algorithms in dynamic and unsure environments inside of a unified framework. the incentive for this e-book arises from the truth that some extent of uncertainty in characterizing any sensible engineering structures is inevitable.

Get Simulation of Semiconductor Processes and Devices 2007: PDF

The "Twelfth foreign convention on Simulation of Semiconductor approaches and units" (SISPAD 2007) maintains an extended sequence of meetings and is held in September 2007 on the TU Wien, Vienna, Austria. The convention is the prime discussion board for know-how Computer-Aided layout (TCAD) held alternatingly within the usa, Japan, and Europe.

Vikash Katta, Peter Karpati, Andreas L. Opdahl (auth.),'s The Practice of Enterprise Modeling: Third IFIP WG 8.1 PDF

This quantity constitutes the lawsuits of the 3rd IFIP WG eight. 1 operating convention at the perform of firm Modeling, held in Delft, The Netherlands, in the course of November 9-10, 2010. The aim of the convention is either to foster a greater figuring out of the perform of firm modeling and to enhance its theoretical foundations.

Extra info for Aging study of boiling water reactor high pressure injection systems

Sample text

Steam will continue to be generated after shutdown by residual stored heat and fission product decay heat. Figure 5 shows a typical HPCI system including a steamdriven turbine driving a booster pump, a reduction gear, a main pump (sometimes considered a pump assembly), many valves, high pressure piping, two injection water sources, and the associated instrumentation. All of the HPCI components, except the inboard isolation valve, are located outside primary containment but inside the reactor building.

Pumps are the next most-failed HPCS component, which places them higher on the list than in the HPCI system. 3). While the LER database utilizes 68 cause codes and 30 cause/effect codes, the prominent causes for HPCI and HPCS failures from LER data are listed in Table 16. Resultant component faults and unknown faults are listed more than 80% of the time as the failure cause in the LER database. They describe a component failure that is the result of another failure or that describe an unknown cause, respectively.

The auxiliary oil pump may also be manually started. Both pumps draw from the same reservoir that is an integral part of the turbine baseplate. This reservoir typically has a capacity of approximately 590 L (155 gal). 7 MPa (100 psi) to the turbine stop valve, the control valve operators, and the turbine governor. 26-MPa (38-psi) oil. All oil except that going to the turbine control valve and the turbine stop valve passes through a filter. In addition to the filters, the oil going to the turbine bearings and the main pump passes through the lube oil cooler mounted on the turbine base.